Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13603011

- Product Categories
- Friendly Links
Information Name: | Yunnan steam vortex flowmeter, Sisson from * China, Yunnan steam vortex flowmeter |
Published: | 2015-05-20 |
Validity: | 0 |
Specifications: | Any |
Quantity: | |
Price Description: | |
Detailed Product Description: | BST6800 flameproof pressure transmitters PlantWeb integrated aluminum shell ceramic seal ring package good insulation properties and bi-316L stainless steel explosion-proof fittings through national testing NEPSI flameproof certification system CF-8 cast stainless steel cleats, the pressure level reaches 60MPA green polyurethane coatings and optional CF-8 housing BST6800 series of explosion-proof pressure transmitters are divided into: Intrinsically Safe Pressure Transmitters (proof mark ExiaⅡCT6), explosion-proof pressure transmitter (proof mark ExdⅡCT6). Intrinsically Safe Pressure Transmitter must be used with safety barrier; terminals flameproof explosion-proof pressure transmitter must have an electrical connector box rugged housing. Sisson made BST6800 series flameproof pressure transmitters from design to installation, from maintenance to operations can be optimized to achieve the concept of measurement commonly used in industrial processes chemical vapor vortex flowmeter Yunnan, Yunnan Petrochemical steam vortex flow meter, gas, and other flammable and explosive places. SISEN pressure transmitter common troubleshooting Fault: No output pressure transmitter Reason 1: Check the pressure transmitter power supply is reversed; solution: the power polarity is correct Cause 2: measuring the pressure transmitter power supply Is there 24V DC voltage; Workaround: You must ensure the supply pressure transmitter supply voltage ≥12V (ie pressure transmitter power supply input voltage ≥12V). If there is no power supply Yunnan steam vortex flowmeter wholesale, you should check the circuit is disconnected, instrumentation error is selected (Input impedance should ≤250Ω); and so on. Reason 3: If you are with a header, and checks the header is damaged (the first two lines can short-circuit header, if the short-circuit normal Yunnan direct steam vortex flowmeter, then the header is damaged); solution: Damaged need another header for the table header, Reason 4: The ammeter in series with 24V power supply circuit, check current is normal; solution: if normal then the normal pressure transmitter, the loop should check whether other instruments normal. Cause 5: The power supply is connected to the pressure transmitter power input; solution: the power cord connected to the power terminals. |
Admin>>>
You are the 36921 visitor
Copyright © GuangDong ICP No. 10089450, Automation Equipment Co., Ltd. Guangzhou Sisson All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 36921 visitor
Copyright © GuangDong ICP No. 10089450, Automation Equipment Co., Ltd. Guangzhou Sisson All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility